Select equipment
Data sheets of pressure-reducing desuperheating station, of stop valves, of regulating valves
- Stop Valve
- Gate Valve (Medium Parameters) 2c,1511, 1533, 1126, 1016
- Gate Valve (High Pressure) 1120, 1123, 1156, 1012, 1013, 1015, 880, 881, 882, 883, 884,885, 887
- Check Valve
- Steam Trap
- Safety Valve 7с
- Pulse Valve 8с
- Pulse Valve 112
- Main Safety Valve
- Pulse Valve 586
- Regulating disk valve
- Regulating Rotary Valve 6c
- Regulating Needle Valve with lever actuation
- Regulating Needle Valve 10c and other
- Throttle Control Valve
- Quick-Release Valve
- Butterfly Valve
- Double-Seat Regulating Valve 14с
1511-200-ЦЗ
Destignation | Dn, mm | Pn, MPa | ξ | Torque, N•m | n | D, mm | d, mm | L, mm | l, mm | A, mm | H, mm | DM, mm | Actuator type*** | Weight, kg | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
200 | 10,0 | 450 | 0,9 | 290 | 20 | 220 | 195 | 550 | 120 | 148 | 828 | 320 | 220 |
Convention
Body – steel 20ГСЛ (GOST 108.961.03);
yoke – steel 25Л, steel 20ГСЛ (GOST 977);
cover – steel 20К (GOST 5520), steel 20ГСЛ (GOST 108.961.03);
valve spindle – steel 35 (GOST 1050), steel 25Х1МФ (GOST 20072) with catalytic nitrogenization;
valve disk – steel 20 (GOST 1050) with building-up welding 04Х19Н9С2 (GOST 2246) or 25Х1МФ (GOST 20072) with catalytic nitrogenization;
valve seat – steel 20 (GOST 1050) with building-up welding 04Х19Н9С2 (GOST 2246).
Gate valves are manufactured in accordance with Technical Specification 3741-003-79315310-2007.
Gate valves are used for leak-free cutting off water or steam. These valves are used only for cutting off (opening) pipelines. Connection to pipeline – by welding. Gate valves are operated by means of handwheel, parallel shaft reducer or right-angle reducer, electric drive.
** without electric actuator *** ref. electric drives section