06/05/2009г.

New LRV type injection valve

Tests have been completed and the injection valve 9с-АМК.LRV.50.63.XX has been accepted. This valve is used to complete the Pressure-Reducing and Desuperheating Station capacity 50t/h P1/P2 = 4,0/0,22 MPa, T1/T2 = 440/135 С. The valve uses a disk regulator made with a tolerance of 5 MK and provides zero unregulated leakage (in the closed state). 9c-AMK.LRV.50.63.XX.E provides non-cavitation operation through the use of internal CVT parts.